Muffle furnace installation and use and price introduction
Muffle furnace installation and use and price introduction
2. A thermocouple is inserted into the furnace with 20-50mm, and the gap between the hole and the thermocouple is filled with asbestos rope. It is better to use compensation wire (or insulated steel core wire) to connect the thermocouple to the control. Pay attention to the positive and negative poles and do not connect them in reverse.
3. An additional power switch needs to be installed at the lead-in of the power cord to control the main power supply. In order to ensure safe operation, the electric furnace and the controller must be reliably grounded.
4. Before use, adjust the thermometer indicator to the zero point. When using the compensation wire and cold junction compensator, adjust the mechanical zero point to the reference temperature of the cold junction compensator. When the compensation wire is not used, the mechanical zero point Adjust to zero scale
5. After checking the wiring and confirming that it is correct, cover the controller shell. Adjust the setting pointer of the temperature indicator to the required operating temperature, and then turn on the power. Turn on the power switch. At this time, the green light on the temperature indicating instrument is on, the relay starts to work, the electric furnace is energized, and the ammeter displays the current. As the internal temperature of the electric furnace rises, the pointer of the temperature indicating instrument gradually rises. This phenomenon indicates that the system is working normally.
In addition, the price of the muffle furnace ranges from several hundred to several thousand dollars, and the price varies according to different types and configurations. If necessary, you can contact our customer service.
- prew:Introduction to the chemical vapor deposition process